YJ-D9000 Defibrillator Monitor 
First Aid Medical Equipment Heart Defibrillator

 YJ-D9000 is a professional biphasic defibrillator-monitor suitable

* Compact Durable
* Light weighted defibrillator
* Multi-parameter Patient Monitor Manual defibrillation
* Automated External Defibrillalator(AED) pacer (option)
* 5 Lanquages to choose

First Aid Medical Equipment Heart Defibrillator
SpO2 Module (Options) 
1.Measurement Range: 30~100% +2% ;between 80%~90% others +5%
2.Alarm : User set high and low limit.
3.Alarm Accuracy: t10% within
setting value Alarm time
4.Accuracy: less than 12 sec.
5.Mieditech Pulse Oximeter

 

ECG Monitoring 

1.3-lead ECG cable or 5-lead ECG cable
2.Display: I II AVR AVL AVF V.
3.ECG Size: 0.25 0.5 1 1.5 2 4 cm/mV
4.Heart Rate: 20-300GPM
First Aid Medical Equipment Heart Defibrillator

Display 
1.Screen Type: High-resolution display
2.Screen Size: 8 inch
3.Languages: 5toChoose
4.Sweep Speed: 25mm/sec
5.Information: Heart Rate.Lead/Pads.Alarm On/OffSp2AED Functions and Prompts Alarm
6.Selection and Limits Delivered Energy
7.5 Languages available: English.Russian. Spanish.Chinese.Turkish

Defibrillator 
1.Waveform:Biphasic
2.Charge Time: Less than 7 seconds with a new fully charged battery.
3.Energy Display: Monitor display indicates both selected and delivered energy Charge Prompt
4.Type: Voice and visual prompts.
5.Electrode Impedance Measurement Range:0-250ohmsEGG Monitoring 
1.Patient Connection: 3-lead ECG cable or 5-lead ECG cable paddles.
2.Lead Selection: Displayed on monitor paddles I II AVR AVL AVF V
3.ECG Size: 0.25 0.5 1 1.5 2 4 cm/mV display on monitor.
4.Heart Rate:20-300BPM.
5.Heart Rate Alarm: On/Off displayed on monitor user-selectable
6.Smart Alarms: Beeper/voice prompts indicate shock able rhythm.

SP02 Module [Options]
1.Measurement Range:30~100%+2% between 80%~90% others±5%
2.Alarm Range: User set high limit and low limit.
3.Alarm Accuracy:+10% within setting values.
4.Alarm time Accuracy: less than 12 sec.
5.1-Meditech Pulse Oximeter

Recorder 
1.Paper: 50mm thermal.
2.Speed: 12.5mm/sec25mm/sec50mm/sec. User-selectable 6-second delay
3.Printing Method: High-resolution thermal print head.
4.Print-out Modes: Manual or automatic user-configurable. 5.On/Off Control: Front panel and paddle.
6.Automatic Function: 9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge.

AED Mode
1.AED Function: Auto analyze and charge x3 with
programmable auto energy level selection screen prompts and voice prompts.
2.Shockable Rhythms: Ventricular fibrillation with amplitude >=200uVventricular tachvcardia with rates >=140bpm and ORScomplex wave duration>=140ms
3.Charge Control: Control on device front panel press key on paddle
4.Prompts: Voice and visual prompts.
Technical specifications

 

Technical specifications
Display
Screen Type
High-resolution display
Screen Size
8 inches diagonally
Sweep Speed
25mm/sec
Information
Heart Rate, Lead/Pads, Alarm On/Off, SpO2, AED
Defibrillator
Waveform
 Biphasic
Charge Time
Less than 7 seconds with a new fully charged battery.
Energy Display
Monitor display indicates both selected and delivered energy.
Charge Prompt Type
Voice and visual prompts.
Electrode Impedance Measurement Range
 0- 250 ohms

ECG Monitoring
Patient Connection
3-lead ECG cable, or 5- lead ECG cable, paddles
Lead Selection
Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V.
ECG Size
0.25, 0.5, 1, 1.5, 2, 4 cm/mV display on monitor.
Heart Rate
20-300BPM
Heart Rate Alarm
On/Off displayed on monitor, user-selectable
Smart Alarms
Beeper/voice prompts indicate shock able rhythm
Battery
Type
Rechargeable, Ni- MH battery, 12V
Operating Time
For a new, fully charged battery: 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring. Additional parameters will affect operating time with different functions.

SpO2 Module
Measurement Range
30~100%, ±2% between 80%~90%, others ±5%
Alarm Range
User set high limit and low limit
Alarm Accuracy
 ±10% within setting values
Alarm time Accuracy
less than 12 sec